{"id":5866,"date":"2019-06-27T12:02:32","date_gmt":"2019-06-27T10:02:32","guid":{"rendered":"https:\/\/ertgmbh.de\/hxi\/"},"modified":"2019-06-27T12:02:35","modified_gmt":"2019-06-27T10:02:35","slug":"hxi","status":"publish","type":"page","link":"https:\/\/ertgmbh.de\/en\/hxi\/","title":{"rendered":"HXI"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"5866\" class=\"elementor elementor-5866 elementor-887\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4524457e elementor-section-full_width elementor-hidden-tablet elementor-hidden-phone elementor-section-height-default elementor-section-height-default\" data-id=\"4524457e\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4463d639\" data-id=\"4463d639\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-4fff2dcb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4fff2dcb\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-6b7d2807\" data-id=\"6b7d2807\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-553515af elementor-align-left elementor-mobile-align-center elementor-hidden-phone elementor-widget elementor-widget-global elementor-global-1973 elementor-widget-breadcrumbs\" data-id=\"553515af\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"breadcrumbs.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p id=\"breadcrumbs\"><span><span><a href=\"https:\/\/ertgmbh.de\/en\/\">Startseite<\/a><\/span><\/span><\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-47f60e46\" data-id=\"47f60e46\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4813948e elementor-align-right elementor-widget elementor-widget-button\" data-id=\"4813948e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"\/?page_id=49\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Contact us!<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-223743a6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"223743a6\" data-element_type=\"section\" data-e-type=\"section\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t\t<div class=\"elementor-background-overlay\"><\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5b713b5c\" data-id=\"5b713b5c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cd93713 elementor-widget elementor-widget-heading\" data-id=\"cd93713\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Hybrid cooler | HXI<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-43edf9eb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"43edf9eb\" data-element_type=\"section\" data-e-type=\"section\" id=\"section-1\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6e21c91e\" data-id=\"6e21c91e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-38c262d5 elementor-widget elementor-widget-heading\" data-id=\"38c262d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">HXI - Hybrid cooling tower with closed cooling circuit<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-bac8972 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bac8972\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-89760a7\" data-id=\"89760a7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-30ad1c8a elementor-widget elementor-widget-text-editor\" data-id=\"30ad1c8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The HXI hybrid cooling tower is an axial multi-flow cooling tower for an output range up to 1,630 kW with a maximum air inlet temperature of 82\u00b0C. The HXI hybrid cooling tower is designed for a maximum air inlet temperature of 82\u00b0C. It has a closed cooling circuit and combines the advantages of evaporative coolers with those of dry cooling (sensitive cooling). The HXI provides full thermal rating for a wide range of flow rates and temperatures. Characteristic advantages of this hybrid recooler include exhaust air heating to avoid steam and considerable water savings compared to conventional evaporative coolers. Standard design features meet today&#8217;s environmental requirements, minimize installation costs, maximize reliable year-round operation and simplify maintenance.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-9b94f15\" data-id=\"9b94f15\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4839246c elementor-arrows-position-inside elementor-pagination-position-outside elementor-widget elementor-widget-image-carousel\" data-id=\"4839246c\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;slides_to_show&quot;:&quot;1&quot;,&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;effect&quot;:&quot;slide&quot;,&quot;speed&quot;:500}\" data-widget_type=\"image-carousel.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-image-carousel-wrapper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Image Carousel\" dir=\"ltr\">\n\t\t\t<div class=\"elementor-image-carousel swiper-wrapper\" aria-live=\"off\">\n\t\t\t\t\t\t\t\t<div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"1 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg\" alt=\"HXI City Center Hamburg 100_0237\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"2 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL-Hybridcooler-switching-cabinet-container-IMG_1195-1-nxuamjk84kpgxenly8sygua6zm1h8aeena762j30hk.jpg\" alt=\"1_HFL Hybridcooler switching cabinet container IMG_1195\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"3 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL-Fraunhofer-CIMG0723-1-nxuamki2beqr90m8sr7l1c1nkzwufzi4zeunjt1mbc.jpg\" alt=\"1_HFL Fraunhofer CIMG0723\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"4 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL-Hybridcooler-foodfactory-1-nxuamlfwi8s1kmkvn9m7ltt46ds7nolvbji5130854.jpg\" alt=\"1_HFL Hybridcooler foodfactory\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"5 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL-Hybridcooler-switching-cabinet-container-DSC03709-1-nxuammdqp2tbw8jihs0u6bkkrrnkvdplno5micytyw.jpg\" alt=\"1_HFL Hybridcooler switching cabinet container DSC03709\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"6 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL-Hybridcooler-switching-cabinet-container-DSC03716-1-nxuamnbkvwum7ui5cafgqtc1d5iy32tbzst3zmxfso.jpg\" alt=\"1_HFL Hybridcooler switching cabinet container DSC03716\" \/><\/figure><\/div><div class=\"swiper-slide\" role=\"group\" aria-roledescription=\"slide\" aria-label=\"7 of 7\"><figure class=\"swiper-slide-inner\"><img decoding=\"async\" class=\"swiper-slide-image\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/1_HFL_installation_1-1-nxuamr2xn8zriacoqc1z0sdvqp0exv89cbf1wqrv3s.jpg\" alt=\"1_HFL_installation_1\" \/><\/figure><\/div>\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-left\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\">\n\t\t\t\t\t\t<i aria-hidden=\"true\" class=\"eicon-chevron-right\"><\/i>\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1e39de1d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1e39de1d\" data-element_type=\"section\" data-e-type=\"section\" id=\"section-2\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-22252727\" data-id=\"22252727\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4ec88b3f elementor-widget elementor-widget-heading\" data-id=\"4ec88b3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Operating principle<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-31fe3ded elementor-widget elementor-widget-text-editor\" data-id=\"31fe3ded\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hybrid coolers can operate in three different modes to suit ambient temperatures and cooling requirements<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36da949a elementor-widget elementor-widget-heading\" data-id=\"36da949a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Dry operation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27a7cf7 elementor-widget elementor-widget-text-editor\" data-id=\"27a7cf7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>During dry operation, the spray water system (1) is switched off and no energy is required for the pumps. The liquid to be cooled (3) first flows through the finned coil (4) and then through the smooth coil (5). The modulating (3-way) flow control valve (2) remains fully open to ensure that both coils maintain the full amount of fluid in series to utilize the maximum heat transfer area. An axial fan (6) sucks in the ambient air (7) via the tube bundle and the heat is dissipated by the liquid in the tube bundle. In this operating mode, no water is consumed and swaths are completely eliminated. HXI cooling towers can be economically selected for dry ball switching points from 10\u00b0 C to 15\u00b0 C or higher, depending on the specific requirements of the project. If the unit is to be operated in dry mode for a longer period of time, it is recommended that the cold water tank be emptied, as no antifreeze or water treatment is required.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-6299f2e2\" data-id=\"6299f2e2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1e653d9b elementor-widget elementor-widget-image\" data-id=\"1e653d9b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"230\" height=\"268\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/ArbeitsprinzipienBAC-HXI_dry_principle_of_operation.png\" class=\"attachment-large size-large wp-image-5867\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\"><\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-729bda09 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"729bda09\" data-element_type=\"section\" data-e-type=\"section\" id=\"section-3\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-4d903922\" data-id=\"4d903922\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-724a0b6b elementor-widget elementor-widget-heading\" data-id=\"724a0b6b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Adiabatic cooling<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dcd6a31 elementor-widget elementor-widget-text-editor\" data-id=\"1dcd6a31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In adiabatic operation, the (3-way) control valve (1) allows the liquid to be cooled (2) to flow alone through the finned coil (3) and the smooth coil (4) is passed completely. A small quantity of circulating spray water (6), which moistens the smooth tube coil and the packed packing (5), serves to saturate and adiabatically precool the incoming external air (7), which is blown over the finned tube coil by an axial fan (8). Under most climatic conditions, the ambient air can still absorb a lot of moisture (9). Therefore the adiabatic cooling of the incoming air leads to significantly lower air temperatures, which in turn considerably prolongs the times of sensitive (dry) heat transfer. The remaining spray water is collected in a tank with a gradient (10) and pumped back into the spray circuit. Compared to conventional evaporative coolers, visible vapors and water consumption are significantly reduced while maintaining the low liquid design temperature required to maximize system efficiency.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-68e3e968\" data-id=\"68e3e968\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-437c5387 elementor-widget elementor-widget-image\" data-id=\"437c5387\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"361\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_adiabatic_principle_of_operation.png\" class=\"attachment-large size-large wp-image-5869\" alt=\"\" srcset=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_adiabatic_principle_of_operation.png 300w, https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_adiabatic_principle_of_operation-249x300.png 249w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\"><\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-da7bdcd elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"da7bdcd\" data-element_type=\"section\" data-e-type=\"section\" id=\"section-4\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-1abd85c3\" data-id=\"1abd85c3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7e8b3246 elementor-widget elementor-widget-heading\" data-id=\"7e8b3246\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Wet\/dry operation<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-75f6529b elementor-widget elementor-widget-text-editor\" data-id=\"75f6529b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In this mode, the liquid to be cooled (1) first flows through the dry finned coil (2) and then through the evaporative smooth coil (3) where the cooled liquid leaves the unit (9). Spray water from the cold water basin (10) is pumped into the water distribution system (8) above the smooth coil (11). The humidification of the smooth tube coil enables evaporation cooling. The spray water falls from the smooth coil over the packing (6) and improves heat transfer by cooling the spray water. Air is sucked both over the smooth coil and over the packing, where it is saturated with moisture and absorbs the heat. However, the air is still cold enough to achieve considerable cooling within the finned coil installed at the outlet above the fans (4). Both sensitive and evaporative cooling are used in wet\/dry operation. Compared to conventional evaporation units, the risk of swaths is considerably reduced and even at peak loads, water can be saved considerably. At lower heat loads and\/or low outside temperatures, the proportion of evaporative cooling and thus water utilisation is reduced by gradually reducing the flow through the evaporative tube bundle. This is achieved by a modulating flow control valve arrangement (12) which regulates the temperature of the outlet liquid. This control arrangement ensures maximum use of sensitive cooling in the finned coil and minimum use of evaporative cooling in the smooth coil. The heat transfer method and flow control are arranged to achieve maximum water savings in wet\/dry operation.<\/p>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3373f8a4\" data-id=\"3373f8a4\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-40a65077 elementor-widget elementor-widget-image\" data-id=\"40a65077\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"314\" src=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_wetdry_principle_of_operation.png\" class=\"attachment-large size-large wp-image-5871\" alt=\"\" srcset=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_wetdry_principle_of_operation.png 300w, https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/HXI_wetdry_principle_of_operation-287x300.png 287w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\"><\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e0536a1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e0536a1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cde2068\" data-id=\"cde2068\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d2bd7c7 elementor-widget elementor-widget-heading\" data-id=\"d2bd7c7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Typical Applications are:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37560ab3 elementor-widget elementor-widget-text-editor\" data-id=\"37560ab3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>Medium to large climate and commercial applications<\/li>\n<li>Water saving<\/li>\n<li>swath reduction<\/li>\n<\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17b6935c elementor-widget elementor-widget-heading\" data-id=\"17b6935c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Main advantages of the HFL<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ee1ac38 elementor-widget elementor-widget-text-editor\" data-id=\"3ee1ac38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n<li>No swaths<\/li>\n<li>Highly efficient use of water<\/li>\n<li>Cost saving<\/li>\n<\/ul>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5847669 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5847669\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-279912cd\" data-id=\"279912cd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4056487a elementor-widget elementor-widget-heading\" data-id=\"4056487a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Main advantages in detail<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b566017 elementor-widget elementor-widget-accordion\" data-id=\"6b566017\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"accordion.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion\">\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1801\" class=\"elementor-tab-title\" data-tab=\"1\" role=\"button\" aria-controls=\"elementor-tab-content-1801\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">No swaths<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1801\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"1\" role=\"region\" aria-labelledby=\"elementor-tab-title-1801\"><p>The HXI hybrid cooler offers the choice between evaporative cooling, adiabatic heat transfer and dry cooling. This significantly reduces the formation of swaths. In cold outside temperatures, when the risk of vapour formation is particularly high, the HXI runs in dry operation so that no vapour can form. Even in wet operation, the formation of vapours is reduced by pre-cooling the process liquid in the dry finned tube coil, the finely adjustable quantity of spray water and by heating and drying the blow-off air at the finned tube coil. In dry operation there are no vapours.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1802\" class=\"elementor-tab-title\" data-tab=\"2\" role=\"button\" aria-controls=\"elementor-tab-content-1802\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Highly efficient use of water<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1802\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"2\" role=\"region\" aria-labelledby=\"elementor-tab-title-1802\"><p>The HXI features patented flow control with a 3-way valve for precise adjustment of the liquid outlet temperature. It can be flexibly adapted to the load profile and external conditions by choosing between dry, adiabatic and wet\/dry operation. Even under peak load in wet\/dry operation, it consumes considerably less water than a conventional evaporation recooler because the process liquid is already pre-cooled dry. In some areas, water savings alone can pay for the device in two years.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1803\" class=\"elementor-tab-title\" data-tab=\"3\" role=\"button\" aria-controls=\"elementor-tab-content-1803\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">High-temperature cooling<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1803\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"3\" role=\"region\" aria-labelledby=\"elementor-tab-title-1803\"><p>The finned tube coil allows higher water inlet temperatures than traditional closed-circuit cooling towers because the incoming liquid is (pre)cooled dry. In this part of the process neither water consumption nor vapour formation takes place.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1804\" class=\"elementor-tab-title\" data-tab=\"4\" role=\"button\" aria-controls=\"elementor-tab-content-1804\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Energy-efficient & cost-saving<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1804\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"4\" role=\"region\" aria-labelledby=\"elementor-tab-title-1804\"><p>The energy consumption of the HXI is very low due to its highly efficient axial fans with low kW output and a motor system with several fans. In dry operation, there is no need for any energy for the pumps. The unique evaporative cooling PLUS with its combined heat transfer system saves energy system-wide. The low water consumption also lowers operating costs, and this is accompanied by lower water treatment costs. In addition, the use of a closed cooling circuit prevents impurities in the process. A simple inspection and maintenance does not only lead to a higher operational safety and a longer service life, but also saves maintenance costs.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1805\" class=\"elementor-tab-title\" data-tab=\"5\" role=\"button\" aria-controls=\"elementor-tab-content-1805\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Low maintenance & easy inspection<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1805\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"5\" role=\"region\" aria-labelledby=\"elementor-tab-title-1805\"><p>The HXI cooling tower has a large hinged door that provides convenient access to the internal catwalk in the spacious maintenance channel so it can be maintained and inspected standing up. The patented multi-current technology reduces evaporation directly from the tube bundle, reducing the risk of deposits as the parallel flow of air and spray water virtually eliminates dry spots. The tube bundles can be inspected from the outside during operation and also from the inside via the removable droplet separator modules. The patented BACross packing steel sheets reduce fouling and allow easy inspection without disassembly. They are accessible from the inside as well as from the outside via the removable air intake protection elements. Optional BACross filling packages are available for quick cleaning and easy removal of the packing. The inclined position of the filling material and the slope of the cold water basin lead to a continuous self-cleaning by rinsing out dirt and foreign bodies. The HXI has anti-turbulence structures with a removable suction strainer. The fresh water and the overflow are easily accessible from the outside for inspection and cleaning.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1806\" class=\"elementor-tab-title\" data-tab=\"6\" role=\"button\" aria-controls=\"elementor-tab-content-1806\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Flexible operation<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1806\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"6\" role=\"region\" aria-labelledby=\"elementor-tab-title-1806\"><p>The multi-blower motor system consists of an independent fan motor and one drive assembly per fan with a maintenance duct section for independent fan operation for additional performance control or as a standby fan in the event of a fan failure. The use of various corrosion-resistant materials, such as the unique Baltibond hybrid coating, guarantees a long service life of the HXI hybrid cooling towers. The one-sided air inlet and air outlet is suitable for most installation conditions. The patented heat transfer system, consisting of multi-flow technology, heat exchanger coil and packing, is ideal for applications where temperature fine tuning is required as well as thermal challenges. The patented intelligent flow control ensures that the outlet temperature remains constant and that the energy and water consumption is as low as possible.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-accordion-item\">\n\t\t\t\t\t<div id=\"elementor-tab-title-1807\" class=\"elementor-tab-title\" data-tab=\"7\" role=\"button\" aria-controls=\"elementor-tab-content-1807\" aria-expanded=\"false\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon elementor-accordion-icon-left\" aria-hidden=\"true\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-closed\"><i class=\"fas fa-plus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t<span class=\"elementor-accordion-icon-opened\"><i class=\"fas fa-minus\"><\/i><\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-accordion-title\" tabindex=\"0\">Maximum operational safety<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t<div id=\"elementor-tab-content-1807\" class=\"elementor-tab-content elementor-clearfix\" data-tab=\"7\" role=\"region\" aria-labelledby=\"elementor-tab-title-1807\"><p>The easy cleaning and inspection of the HXI reduces the hygiene risks due to bacteria and biofilm inside the HXI. The combined air inlet protection elements block sunlight and thus prevent biological growth in the tower. They also filter the air and ensure that no water splashes outside. The patented BACross filler reduces fouling and Eurovent certified droplet separators prevent droplets from getting into the air.<\/p>\n<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-30f85757 elementor-hidden-phone elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"30f85757\" data-element_type=\"section\" data-e-type=\"section\" id=\"section-4\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-no\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-45d09be5\" data-id=\"45d09be5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-27213cf9 elementor-cta--layout-image-left elementor-bg-transform elementor-bg-transform-zoom-out elementor-cta--skin-classic elementor-animated-content elementor-widget elementor-widget-call-to-action\" data-id=\"27213cf9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"call-to-action.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-cta\">\n\t\t\t\t\t<div class=\"elementor-cta__bg-wrapper\">\n\t\t\t\t<div class=\"elementor-cta__bg elementor-bg\" style=\"background-image: url(https:\/\/ertgmbh.de\/wp-content\/uploads\/2019\/05\/water-hero-wassertechnik.jpg);\" role=\"img\" aria-label=\"&quot;&quot;\"><\/div>\n\t\t\t\t<div class=\"elementor-cta__bg-overlay\"><\/div>\n\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"elementor-cta__content\">\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<h4 class=\"elementor-cta__title elementor-cta__content-item elementor-content-item\">\n\t\t\t\t\t\tGo to next product\t\t\t\t\t<\/h4>\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-cta__button-wrapper elementor-cta__content-item elementor-content-item \">\n\t\t\t\t\t<a class=\"elementor-cta__button elementor-button elementor-size-\" href=\"https:\/\/ertgmbh.de\/en\/hfl\/\">\n\t\t\t\t\t\tHFL\t\t\t\t\t<\/a>\n\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6a75ab01 elementor-hidden-desktop elementor-hidden-tablet elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6a75ab01\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-73593301\" data-id=\"73593301\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-291259cc elementor-widget elementor-widget-heading\" data-id=\"291259cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Go to next product<\/h4>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-74544aa9 elementor-mobile-align-center elementor-widget elementor-widget-button\" data-id=\"74544aa9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-xl\" href=\"https:\/\/ertgmbh.de\/en\/hfl\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">HFL<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Contact us! Hybrid cooler | HXI HXI &#8211; Hybrid cooling tower with closed cooling circuit The HXI hybrid cooling tower is an axial multi-flow cooling tower for an output range up to 1,630 kW with a maximum air inlet temperature of 82\u00b0C. The HXI hybrid cooling tower is designed for a maximum air inlet temperature [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"ocean_post_layout":"","ocean_both_sidebars_style":"","ocean_both_sidebars_content_width":0,"ocean_both_sidebars_sidebars_width":0,"ocean_sidebar":"0","ocean_second_sidebar":"0","ocean_disable_margins":"enable","ocean_add_body_class":"","ocean_shortcode_before_top_bar":"","ocean_shortcode_after_top_bar":"","ocean_shortcode_before_header":"","ocean_shortcode_after_header":"","ocean_has_shortcode":"","ocean_shortcode_after_title":"","ocean_shortcode_before_footer_widgets":"","ocean_shortcode_after_footer_widgets":"","ocean_shortcode_before_footer_bottom":"","ocean_shortcode_after_footer_bottom":"","ocean_display_top_bar":"default","ocean_display_header":"default","ocean_header_style":"","ocean_center_header_left_menu":"0","ocean_custom_header_template":"0","ocean_custom_logo":0,"ocean_custom_retina_logo":0,"ocean_custom_logo_max_width":0,"ocean_custom_logo_tablet_max_width":0,"ocean_custom_logo_mobile_max_width":0,"ocean_custom_logo_max_height":0,"ocean_custom_logo_tablet_max_height":0,"ocean_custom_logo_mobile_max_height":0,"ocean_header_custom_menu":"0","ocean_menu_typo_font_family":"0","ocean_menu_typo_font_subset":"","ocean_menu_typo_font_size":0,"ocean_menu_typo_font_size_tablet":0,"ocean_menu_typo_font_size_mobile":0,"ocean_menu_typo_font_size_unit":"px","ocean_menu_typo_font_weight":"","ocean_menu_typo_font_weight_tablet":"","ocean_menu_typo_font_weight_mobile":"","ocean_menu_typo_transform":"","ocean_menu_typo_transform_tablet":"","ocean_menu_typo_transform_mobile":"","ocean_menu_typo_line_height":0,"ocean_menu_typo_line_height_tablet":0,"ocean_menu_typo_line_height_mobile":0,"ocean_menu_typo_line_height_unit":"","ocean_menu_typo_spacing":0,"ocean_menu_typo_spacing_tablet":0,"ocean_menu_typo_spacing_mobile":0,"ocean_menu_typo_spacing_unit":"","ocean_menu_link_color":"","ocean_menu_link_color_hover":"","ocean_menu_link_color_active":"","ocean_menu_link_background":"","ocean_menu_link_hover_background":"","ocean_menu_link_active_background":"","ocean_menu_social_links_bg":"","ocean_menu_social_hover_links_bg":"","ocean_menu_social_links_color":"","ocean_menu_social_hover_links_color":"","ocean_disable_title":"default","ocean_disable_heading":"default","ocean_post_title":"","ocean_post_subheading":"","ocean_post_title_style":"","ocean_post_title_background_color":"","ocean_post_title_background":0,"ocean_post_title_bg_image_position":"","ocean_post_title_bg_image_attachment":"","ocean_post_title_bg_image_repeat":"","ocean_post_title_bg_image_size":"","ocean_post_title_height":0,"ocean_post_title_bg_overlay":0.5,"ocean_post_title_bg_overlay_color":"","ocean_disable_breadcrumbs":"default","ocean_breadcrumbs_color":"","ocean_breadcrumbs_separator_color":"","ocean_breadcrumbs_links_color":"","ocean_breadcrumbs_links_hover_color":"","ocean_display_footer_widgets":"default","ocean_display_footer_bottom":"default","ocean_custom_footer_template":"0","footnotes":""},"class_list":["post-5866","page","type-page","status-publish","hentry","entry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HXI - ERT Refrigeration Technology GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/ertgmbh.de\/en\/hxi\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HXI - ERT Refrigeration Technology GmbH\" \/>\n<meta property=\"og:description\" content=\"Contact us! Hybrid cooler | HXI HXI &#8211; Hybrid cooling tower with closed cooling circuit The HXI hybrid cooling tower is an axial multi-flow cooling tower for an output range up to 1,630 kW with a maximum air inlet temperature of 82\u00b0C. The HXI hybrid cooling tower is designed for a maximum air inlet temperature [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/ertgmbh.de\/en\/hxi\/\" \/>\n<meta property=\"og:site_name\" content=\"ERT Refrigeration Technology GmbH\" \/>\n<meta property=\"article:modified_time\" content=\"2019-06-27T10:02:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/\",\"url\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/\",\"name\":\"HXI - ERT Refrigeration Technology GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/ertgmbh.de\\\/wp-content\\\/uploads\\\/elementor\\\/thumbs\\\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg\",\"datePublished\":\"2019-06-27T10:02:32+00:00\",\"dateModified\":\"2019-06-27T10:02:35+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/#primaryimage\",\"url\":\"https:\\\/\\\/ertgmbh.de\\\/wp-content\\\/uploads\\\/elementor\\\/thumbs\\\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg\",\"contentUrl\":\"https:\\\/\\\/ertgmbh.de\\\/wp-content\\\/uploads\\\/elementor\\\/thumbs\\\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/hxi\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HXI\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/\",\"name\":\"ERT Refrigeration Technology GmbH\",\"description\":\"ERT Refrigeration Technology GmbH\",\"publisher\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#organization\",\"name\":\"ERT Refrigeration Technology GmbH\",\"url\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/ertgmbh.de\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/cropped-logo_ert_FINAL-1.png\",\"contentUrl\":\"https:\\\/\\\/ertgmbh.de\\\/wp-content\\\/uploads\\\/2018\\\/10\\\/cropped-logo_ert_FINAL-1.png\",\"width\":600,\"height\":207,\"caption\":\"ERT Refrigeration Technology GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/ertgmbh.de\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HXI - ERT Refrigeration Technology GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/ertgmbh.de\/en\/hxi\/","og_locale":"en_US","og_type":"article","og_title":"HXI - ERT Refrigeration Technology GmbH","og_description":"Contact us! Hybrid cooler | HXI HXI &#8211; Hybrid cooling tower with closed cooling circuit The HXI hybrid cooling tower is an axial multi-flow cooling tower for an output range up to 1,630 kW with a maximum air inlet temperature of 82\u00b0C. The HXI hybrid cooling tower is designed for a maximum air inlet temperature [&hellip;]","og_url":"https:\/\/ertgmbh.de\/en\/hxi\/","og_site_name":"ERT Refrigeration Technology GmbH","article_modified_time":"2019-06-27T10:02:35+00:00","og_image":[{"url":"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/ertgmbh.de\/en\/hxi\/","url":"https:\/\/ertgmbh.de\/en\/hxi\/","name":"HXI - ERT Refrigeration Technology GmbH","isPartOf":{"@id":"https:\/\/ertgmbh.de\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/ertgmbh.de\/en\/hxi\/#primaryimage"},"image":{"@id":"https:\/\/ertgmbh.de\/en\/hxi\/#primaryimage"},"thumbnailUrl":"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg","datePublished":"2019-06-27T10:02:32+00:00","dateModified":"2019-06-27T10:02:35+00:00","breadcrumb":{"@id":"https:\/\/ertgmbh.de\/en\/hxi\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/ertgmbh.de\/en\/hxi\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ertgmbh.de\/en\/hxi\/#primaryimage","url":"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg","contentUrl":"https:\/\/ertgmbh.de\/wp-content\/uploads\/elementor\/thumbs\/HXI-City-Center-Hamburg-100_0237-1-nxuaftzpc5is1mei4udu618qbl45a2re22jdqf16wo.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/ertgmbh.de\/en\/hxi\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/ertgmbh.de\/en\/"},{"@type":"ListItem","position":2,"name":"HXI"}]},{"@type":"WebSite","@id":"https:\/\/ertgmbh.de\/en\/#website","url":"https:\/\/ertgmbh.de\/en\/","name":"ERT Refrigeration Technology GmbH","description":"ERT Refrigeration Technology GmbH","publisher":{"@id":"https:\/\/ertgmbh.de\/en\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/ertgmbh.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/ertgmbh.de\/en\/#organization","name":"ERT Refrigeration Technology GmbH","url":"https:\/\/ertgmbh.de\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/ertgmbh.de\/en\/#\/schema\/logo\/image\/","url":"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/cropped-logo_ert_FINAL-1.png","contentUrl":"https:\/\/ertgmbh.de\/wp-content\/uploads\/2018\/10\/cropped-logo_ert_FINAL-1.png","width":600,"height":207,"caption":"ERT Refrigeration Technology GmbH"},"image":{"@id":"https:\/\/ertgmbh.de\/en\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/pages\/5866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/comments?post=5866"}],"version-history":[{"count":2,"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/pages\/5866\/revisions"}],"predecessor-version":[{"id":5874,"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/pages\/5866\/revisions\/5874"}],"wp:attachment":[{"href":"https:\/\/ertgmbh.de\/en\/wp-json\/wp\/v2\/media?parent=5866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}